| pumped media, it is frequently
necessary to flush the quench space to prevent build
up of deposits under the primary seal faces. This is
the normal condition in which the minute amount of normal
leakage crytallise or decompose into deposits which
can inhibit seal flexibility and shorten seal life.
The CF600 contains liquid quenches with the pressure
restrictions encountered through the use of lip-seals,
throttle bushings, labyrinths or other secondary containment
devices. This has the benefit of eliminating spray leakage
from the gland area and preventing ingress of quench
media to the bearings.
The CF600 is exceptionally easy to install, only requiring
the seal plate to be bolted to the seal chamber and
the sleeve locked to the shaft. There are no awkward
setting clips to remove.
|